Solid Sawn Studs

Studs are a series of vertical load bearing members used to support elements in walls and partitions. Studs in exterior walls of one and two-story buildings are at least nominal 2x4 inches with the 4-inch dimension forming the basic wall thickness. Stud spacing is normally 16 inches in exterior walls, although 24-inch spacing of 2x4 studs is acceptable in one-story buildings if wall sheathing or siding is of adequate thickness to bridge across studs. In three-story buildings studs in the bottom story are at least nominal 3x4 or 2x6 inches and may not exceed 16-inch spacing. Studs are arranged in multiples at corners and partition intersections to provide for rigid attachment of sheathing, siding and interior wall finish materials. Nailing strips or metal clips may be used to back up interior finish at corners.

img
A grademark identifies the species, grade, grading agency, and mill number. This information allows the product to be traced to the mill of origin, as well as establishing the structural properties of the piece of lumber.
img
Most 2x4 dimension lumber is visually graded and marked with an ink stamp at the mill. The markings on this bunk of lumber provide information to assure the product has the strength for the application.
The exterior wall is framed with OSB sheathing and lumber studs. 2x4 blocking is installed as firestopping where the exterior wall and the cathedral ceiling intersect. The cathedral ceiling is created using pitched chord trusses.
img
Headers require multiply studs for end bearing to support floor and roof loads from stories above. Most builders use two top-plates in wall construction.
img
Once the exterior wall sheathing is attached, the exterior wall framing is no longer visible. This typical framing drawings details how headers and walls studs are used to construct an exterior wall.
img
This exterior wall cut-away reveals the wall framing.
img
Exterior wall framing supporting parallel chord trusses.
img
Typical wall framing is reveled beneath the gypsum wallboard sheathing.
img
Walls are typically framed with double top-plates. Piping and wiring penetrate the double-top plate.
img
"Lumber is commonly available in nominal 2"" thickness and widths of 4"" to 12""."
img
OSB floor and wall sheathing is combined with lumber floor joists, wall studs and headers in this traditional whole-house framing package.
img
Wall studs in balloon framing are continuous for the total height of the wall. Floor joists supported n a ledger that is attached to the studs. Balloon framing must be firestopped in accordance with the building code.
img
Continuous exterior wall studs in balloon framing. Firestopping is necessary to isolate the vertical and horizontal cavities and to limited the height of the wall cavity.
img
Elements of a stud wall.
img
An interior bearing wall is used to support an I-joist floor framing system.